Protege EliteSuite Eclipse Manual de instalación Pagina 46

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 56
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 45
,2, 4, [toggle opons], Panic Alarm opons
Opon Descripon Default
1 Enable [1] + [3] Panic alarm Disabled
2 Enable [4] + [6] Medical alarm Disabled
3 Enable [7] + [9] Fire alarm Disabled
4 Enable Duress code Disabled
5-8 Reserved Disabled
,3, [select zone], Select Zone
[select zone type], Select Zone Type
Type Descripon
1 Disabled
2 Delay - Zone has an entry delay
3 Follow - Instant but not if another Zone has already
triggered the entry delay
4 Instant - Zone will trigger instantly
5 24hr - Zone will always cause an alarm immediately
6 Fire - Zone will trigger a Fire alarm instantly
7 Fire delay - Zone will trigger a Fire alarm aer 30s delay
8 Reserved
[select zone opon], Select Zone Opon
Opon Descripon
1 Bypass allowed
2 Stay Zone enable
3 Force Zone enable
4-8 Reserved
43