15.2 Installer Menu
To enter the Installer menu press the ENTER key ( ), then enter the four digit Installer code.
Key Sequence Descripon
,1, 1, View the Entry Delay Timer
,1, 1, [T1], [T2], [T3], Change the current Entry Delay Timer
,1, 2, View the current Exit Delay Timer
,1, 1, [T1], [T2], [T3], Change the current Exit Delay Timer
,1, 3, View the current Siren Timer
,1, 1, [T1], [T2], [T3], Change the current Siren Timer
,2, 1, [toggle opons], General sengs
Opon Descripon Default
1 Enable EOL Zone Opon (1k + 1k) Disabled
2 Enable Duplex Zone opon (8 zones) Disabled
3 Beep on trouble condion Disabled
4 Power up disarmed Disabled
5 Reserved Disabled
6 PGM output follows alarm state Enabled
7 PGM output follows area state Disabled
8 PGM output inversion Disabled
,2, 2, [toggle opons], Arming Opons
Opon Descripon Default
1 Allow Fast Regular arming Enabled
2 Allow Fast Stay arming Enabled
3 Allow Instant Arming during Stay exit Enabled
4 Allow Fast Force arming Enabled
5-8 Reserved Disabled
,2, 3, [toggle opons], Reporng Opons
Opon Descripon Default
1 Report Arming and Disarming Enabled
2 Report Alarms Enabled
3 Report Zone Bypass Disabled
4 Report Zone Fault Disabled
5 Report User Menu access Disabled
6 Report Local Install Menu access Disabled
7 Report Extended Informaon Disabled
8 Reserved Disabled