11.0 Timing (Menu 1)
11.1EntryDelayTimer(Menu1,1)
The Entry Delay Timer is programmable from 000 to 255 seconds (default 30 seconds).
To View the Timer Value
Step 1
To view the Timer value enter the following key press sequence:
, 1, 1,
The Timer value will be displayed as a sequence of three Number LED’s lighng one aer the other
corresponding to each of the three digits of the mer.
To Program the Timer Value
Step 1
To program the Timer value enter the following key press sequence:
, 1, 1, [TIM 1], [TIM 2], [TIM 3],
Where TIM 1 to 3 are the Timer value digits, entered using the 0 to 9 number keys.
Programming the Entry Delay Timer to 0 will result in no entry delay operaon for any zone that
has been assigned the entry delay Zone Type.
Example:Thesequence,1,1,0,3,0,,setsthemerto30seconds
11.2ExitDelayTimer(Menu1,2)
The Exit Delay Timer is programmable from 000 to 255 seconds (default 30 seconds).
To View the Timer Value
Step 1
To view the Timer value enter the following key press sequence:
, 1, 2,
The Timer value will be displayed as a sequence of three number LED’s lighng one aer the other
corresponding to each of the three digits of the mer.
21