Protege EliteSuite Eclipse Manual de instalación Pagina 25

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 56
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 24
!
All three digits of the Timer value must be entered when programming a mer.
This means that for mes below 100, you must enter [0] then the two digits of the
me. For mes below 10, you must enter [0], [0] followed by the me digit.
To Program the Timer Value
Step 1
To program the Timer value enter the following key press sequence:
, 1, 2, [TIM 1], [TIM 2], [TIM 3],
Where TIM 1 to 3 are the Timer value digits, entered using the 0 to 9 number keys.
Programming the Exit Delay Timer to 0 will result in no exit delay, the system will immediately arm
the EliteSuite® System.
Example:Thesequence,1,2,0,4,5,,setsthemerto45seconds
11.3Alarm/SirenTimer(Menu1,3)
The Alarm/Siren mer is programmed from 000 to 250 minutes (default 4 minutes).
To View the Timer Value
Step 1
To view the Timer value enter the following key press sequence:
, 1, 3,
The Timer value will be displayed as a sequence of three number LED’s lighng one aer the other
corresponding to each of the three digits of the mer.
To Program the Timer Value
Step 1
To program the Timer value enter the following key press sequence:
, 1, 3, [TIM 1], [TIM 2], [TIM 3],
Where TIM 1 to 3 are the mer value digits, entered using the 0 to 9 number keys.
Example:Thesequence,1,3,0,0,5,,setsthemertoveminutes
22
Vista de pagina 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 55 56

Comentarios a estos manuales